Key takeaways
- A city permit inspection checks new work against the code. A condition or maintenance inspection checks the whole system as it stands.
- Insurers, lenders and buyers often ask for a condition survey; NFPA 70B is the national document for electrical maintenance programs.
- OSHA's electrical rules for workplaces cover items an inspection should catch, such as working space at panels and labeled disconnects.
A commercial electrical inspection can mean several things: a city inspector signing off new work, an insurer asking for a condition report, or a planned maintenance check under a maintenance agreement. Knowing which one you need saves time and money. Our commercial electrical page covers the work behind each.
What types of commercial electrical inspection are there?
- A permit inspection, by the city, of new or altered work against the adopted code.
- A change of occupancy or certificate of occupancy inspection when a space changes use or tenant.
- A condition survey for an insurer, a lender or a buyer.
- A preventive maintenance inspection, often with infrared, on a planned schedule.
What does a city permit inspection check?
A permit inspection checks the work the permit covers against the code the city has adopted. In San Antonio, that code and its local changes are in Chapter 10 of the City Code. The inspector looks at rough wiring before walls close and at the finished work before power is released or the space is occupied. Our posts on how commercial electrical permits work in San Antonio and change of occupancy cover those steps.
What does a condition or maintenance inspection cover?
A condition inspection looks at the whole system as it stands: the service, switchboards, panels, transformers, disconnects, grounding and bonding, emergency lighting and the condition of the wiring. It notes overheating, corrosion, missing covers, open knockouts, unlabeled circuits and equipment near the end of its life.
NFPA 70B is the national document for electrical equipment maintenance. It ties how often equipment is maintained to the condition the equipment is in. Infrared scanning under load is a common part of the work; our post on infrared thermography explains it.
What workplace safety items does an inspection catch?
OSHA's general electrical rule for workplaces, 29 CFR 1910.303, requires clear working space in front of electrical equipment, disconnects marked to show what they serve, and equipment free of hazards. Storage in front of a panel and unlabeled breakers are among the most common findings.
What happens with the findings?
A good report ranks each finding: hazards that need action now, items to plan for, and notes for the record. Repairs to the electrical system are done by a licensed contractor, and in Texas electricians are licensed by TDLR. Some repairs then need a permit and a city inspection of their own.
How often should a commercial building be inspected?
That depends on the building, the equipment's condition, the insurer and any maintenance program in place. Standby generators have their own testing schedule; our post on load bank testing covers it.
What should I do next?
Tell us which inspection you need and why: a permit, an insurer, a sale or a maintenance plan. Send the building's size, its use and any past reports. Book a site visit and you get a written price before any work starts.